POWER SYM PRO is proud to bring innovative and reliable solutions for power system protection, control and automation. These products are divided into three main categories; Basic, Intermediate and Advanced Functions.
Test Block is a testing Module that is used together with test plugs in the field of relay protection. It is capable of quickly separating input side (voltage, current, auxiliary power supply, etc.) of relay protection device from the output loop, meanwhile ensure reliable short connection of external CT to simplify the testing process of the device
A tripping relay is a high burden self-reset tripping relay suitable for application in high-security circuit breaker tripping circuits & in particular where the initiating contact may be remote from the relay. The high burden may also allow the satisfactory operation of external series elements.
DC Supervision Relay monitors the DC supply source, detects loss of DC voltage supply, open circuits, or simply as drop-off delayed relay in automation circuits. A typical application is the continuous supervision of a circuit.
Protection against motor burnout during an overload or locked rotor, and offers a wide range of specifications to meet various needs, including protection against overload and phase loss, time lag, quick connect, etc. Usable in general applications such as motor starting, stopping, and burnout protection. When an overcurrent continues by flow due to motor overload, or constraint, it is detected with a thermal relay before the motor burnout.
Relay provides complete protection for radial and looped distribution circuits. It offers arc-flash mitigation, fault location, high-impedance fault detection, broken conductor detection, event analysis, and more. You can quickly integrate the relay into serial- or Ethernet-based communications with IEC 61850 Edition 2, IEC 60870-5-103, the IEC 62439 Parallel Redundancy Protocol (PRP), Ethernet/IP, the IEEE 1588 Precision Time Protocol (PTP), Modbus, DNP3, and other protocols. It Maximizes control scheme flexibility using time- and instantaneous-overcurrent, overvoltage, under-voltage, directional power, and frequency elements, with breaker failure protection for one three-pole breaker. Second- and fifth-harmonic blocking improves protection security during magnetizing inrush conditions caused by line re-energization, or by voltage recovery after any out-of-zone fault.